Performance evaluation of U-pipe type evacuated tube collector at low air flow rates: An experimental study

Authors

  • Satish Kumar Gavel
  • Gajendra Kumar Agrawal
  • T.V. Arjunan
  • Indulata Kanwar

DOI:

https://doi.org/10.22399/ijcesen.5472

Keywords:

ETC, Temperature rise, Thermal efficiency, Copper fin temperature, Pressure drop

Abstract

 

 

Solar energy is regarded as one of the most favoured forms of renewable energy. Different researchers have proposed various kinds of solar collectors with distinct design changes and operating conditions. Among different types of solar collectors, the evacuated tube collector (ETC) stands out due to its significantly low convective heat losses from the absorber plate. The U-pipe setup within the evacuated tube is popular because of its straightforward design and ability to withstand the high pressure of the working fluid. Numerous theoretical and experimental investigations of U-pipe type ETC with diverse design alterations have been conducted by different researchers. An effort is made to assess the efficiency of a U-pipe type ETC for air flow rates between 1 kg/hr to 4 kg/hr. Experiments were conducted in Bilaspur, Chhattisgarh, India, during four distinct months from November 2024 to May 2025. The monthly average values of peak solar intensities were recorded as 950 W/m2, 973 W/m2, 1055 W/m2, and 1088 W/m2 for the months of November, February, April, and May, respectively. The peak rise in air temperature and the highest temperatures of copper fins were recorded at 63.7 °C and 179.9 °C, respectively, which corresponded to a mass flow rate of 1 kg/hr for the month of May; however, the greatest thermal efficiency observed was 36.6% at 4 kg/hr in the April. The maximum values of pressure drop and blower power were determined to be 0.30 KPa and 0.31 W, respectively, at a mass flow rate of 4 kg/hr.

 

References

[1]. Sukhatme, S. P., & Nayak, J. K. (2015). Solar energy (3rd ed.). McGraw Hill Education (India).

[2]. Kalogirou, S. A. (2014). Solar energy engineering (2nd ed.). Academic Press.

[3]. Bakry, A. I., EL-Samadony, Y. A. F., El-Agouz, S. A., Alshrombably, A. M., Abdelfatah, K. S., & Said, M. A. (2018). Performance of the one-ended evacuated tubes as medium temperature solar air heaters at low flow rates. Sustainable Energy Technologies and Assessments, 30, 174-182. DOI: https://doi.org/10.1016/j.seta.2018.10.002

[4]. Wang, Z., Diao, Y., Zhao, Y., Chen, C., Liang, L., & Wang, T. (2020). Thermal performance of integrated collector storage solar air heater with evacuated tube and lap joint-type flat micro-heat pipe arrays. Applied Energy, 261, 114466. DOI: https://doi.org/10.1016/j.apenergy.2019.114466

[5]. Singh, I., & Vardhan, S. (2021). Experimental investigation of an evacuated tube collector solar air heater with helical inserts. Renewable Energy, 163, 1963-1972. DOI: https://doi.org/10.1016/j.renene.2020.10.114

[6]. Al-Joboory, H. N. S. (2019). Comparative experimental investigation of two evacuated tube solar water heaters of different configurations for domestic application of Baghdad, Iraq. Energy & Buildings, 203, 109437. DOI: https://doi.org/10.1016/j.enbuild.2019.109437

[7]. Kumar, P. M., & Mylsamy, K. (2020). A comprehensive study on thermal storage characteristics of nano-CeO₂ embedded phase change material and its influence on the performance of evacuated tube solar water heater. Renewable Energy, 162, 662-676. DOI: https://doi.org/10.1016/j.renene.2020.08.122

[8]. Wang, P.-Y., Guan, H.-Y., Liu, Z.-H., Wang, G.-S., Zhao, F., & Xiao, H.-S. (2014). High temperature collecting performance of a new all-glass evacuated tubular solar air heater with U-shaped tube heat exchanger. Energy Conversion and Management, 77, 315-323. DOI: https://doi.org/10.1016/j.enconman.2013.08.019

[9]. Wang, P.-Y., Li, S.-F., & Liu, Z.-H. (2015). Collecting performance of an evacuated tubular solar high-temperature air heater with concentric tube heat exchanger. Energy Conversion and Management, 106, 1166-1173. DOI: https://doi.org/10.1016/j.enconman.2015.10.058

[10]. Wannagosit, C., Sakulchangsatjatai, P., Kammuang-lue, N., & Terdtoon, P. (2018). Validated mathematical models of a solar water heater system with thermosyphon evacuated tube collectors. Case Studies in Thermal Engineering, 12, 528-536. DOI: https://doi.org/10.1016/j.csite.2018.07.005

[11]. Essa, M. A., Rofaiel, I. Y., & Ahmed, M. A. (2020). Experimental and theoretical analysis for the performance of evacuated tube collector integrated with helical finned heat pipes using PCM energy storage. Energy, 206, 118166. DOI: https://doi.org/10.1016/j.energy.2020.118166

[12]. D. S. N., R. S., Kumar, P. M., Subbiah, R., Karthick, A., & S. P. T. (2021). Study on an ETC solar water heater using flat and wavy diffuse reflectors. Materials Today: Proceedings, 47, 5228-5232. DOI: https://doi.org/10.1016/j.matpr.2021.05.561

[13]. Gunasekaran, N., Kumar, P. M., Raja, S., Sharavanan, S., Avinas, K., Aakash Kannan, P., & Gokul, S. (2021). Investigation on ETC solar water heater using twisted tape inserts. Materials Today: Proceedings, 47, 5011-5016. DOI: https://doi.org/10.1016/j.matpr.2021.04.586

[14]. Veera Kumar, A., Arjunan, T. V., Seenivasan, D., Venkatramanan, R., Vijayan, S., & Matheswaran, M. M. (2021). Influence of twisted tape inserts on energy and exergy performance of an evacuated tube-based solar air collector. Solar Energy, 225, 892-904. DOI: https://doi.org/10.1016/j.solener.2021.07.074

[15]. Alshukri, M. J., Eidan, A. A., & Najim, S. I. (2021). Thermal performance of heat pipe evacuated tube solar collector integrated with different types of phase change materials at various locations. Renewable Energy, 171, 635-646. DOI: https://doi.org/10.1016/j.renene.2021.02.143

[16]. Afshari, F., Seozen, A., Khanlari, A., Tuncer, A. D., & Sirin, C. (2020). Effect of turbulator modifications on the thermal performance of cost-effective alternative solar air heater. Renewable Energy, 158, 297-310. DOI: https://doi.org/10.1016/j.renene.2020.05.148

[17]. Bracamonte, J., Parada, J., Dimas, J., & Baritto, M. (2015). Effect of the collector tilt angle on thermal efficiency and stratification of passive water in glass evacuated tube solar water heater. Applied Energy, 155, 648-659. DOI: https://doi.org/10.1016/j.apenergy.2015.06.008

[18]. Elarem, R., Alqahtani, T., Mellouli, S., Aich, W., Khedher, N. B., Kolsi, L., & Jemni, A. (2021). Numerical study of an evacuated tube solar collector incorporating a Nano-PCM as a latent heat storage system. Case Studies in Thermal Engineering, 24, 100859. DOI: https://doi.org/10.1016/j.csite.2021.100859

[19]. Famiglietti, A., Lecuona-Neumann, A., Nogueira, J., & Rahjoo, M. (2020). Direct solar production of medium temperature hot air for industrial applications in linear concentrating solar collectors using an open Brayton cycle viability analysis. Applied Thermal Engineering, 169, 114914. DOI: https://doi.org/10.1016/j.applthermaleng.2020.114914

[20]. Mehla, N., & Kumar, A. (2021). Experimental evaluation of used engine oil based thermal energy storage coupled with novel evacuated tube solar air collector (NETAC). Journal of Energy Storage, 39, 102656. DOI: https://doi.org/10.1016/j.est.2021.102656

[21]. Mercan, M., & Yurddaş, A. (2019). Numerical analysis of evacuated tube solar collectors using nanofluids. Solar Energy, 191, 167–179. DOI: https://doi.org/10.1016/j.solener.2019.08.074

[22]. Olfian, H., Mousavi Ajarostaghi, S. S., & Ebrahimnataj, M. (2020). Development on evacuated tube solar collectors: A review of the last decade results of using nanofluids. Solar Energy, 211, 265-282. DOI: https://doi.org/10.1016/j.solener.2020.09.056

[23]. Aggarwal, S., Kumar, S., Kumar, R., & Thakur, R. (2021). Thermal augmentation in evacuated tube solar collectors using reflectors, nanofluids, phase change materials and tilt angle: A review. Materials Today: Proceedings, 45, 4931-4935. DOI: https://doi.org/10.1016/j.matpr.2021.01.371

[24]. Kumar, A., Tiwari, A. K., & Said, Z. (2021). A comprehensive review analysis on advances of evacuated tube solar collector using nanofluids and PCM. Sustainable Energy Technologies and Assessments, 47, 101417. DOI: https://doi.org/10.1016/j.seta.2021.101417

[25]. Plante, R. H. (2014). Solar energy, photovoltaics, and domestic hot water: A technical and economic guide for project planners, builders, and property owners. Academic Press.

[26]. Kalogirou, S. A. (2004). Solar thermal collectors and applications. Progress in Energy and Combustion Science, 30(3), 231-295. DOI: https://doi.org/10.1016/j.pecs.2004.02.001

[27]. Kim, Y., & Seo, T. (2007). Thermal performances comparisons of the glass evacuated tube solar collectors with shapes of absorber tube. Renewable Energy, 32(5), 772-795. DOI: https://doi.org/10.1016/j.renene.2006.03.016

[28]. Speyer, E. (1965). Solar energy collection with evacuated tubes. Journal of Engineering for Power, 87(3), 270–276. DOI: https://doi.org/10.1115/1.3678243

[29]. Gong, J. H., Jiang, Z., Luo, X. F., et al. (2020). Straight-through all-glass evacuated tube solar collector for low and medium temperature applications. Solar Energy, 201, 935-943. DOI: https://doi.org/10.1016/j.solener.2020.03.069

[30]. Siuta-Olcha, A., Cholewa, T., & Dopieralska-Howoruszko, K. (2021). Experimental studies of thermal performance of an evacuated tube heat pipe solar collector in Polish climatic conditions. Environmental Science and Pollution Research, 28, 14319-14328. DOI: https://doi.org/10.1007/s11356-020-07920-3

Downloads

Published

2025-09-20

How to Cite

Kumar Gavel, S., Gajendra Kumar Agrawal, T.V. Arjunan, & Indulata Kanwar. (2025). Performance evaluation of U-pipe type evacuated tube collector at low air flow rates: An experimental study. International Journal of Computational and Experimental Science and Engineering, 11(4). https://doi.org/10.22399/ijcesen.5472

Issue

Section

Research Article